Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Korean Journal of Physical Anthropology ; : 187-198, 2010.
Article in English | WPRIM | ID: wpr-37920

ABSTRACT

The sectioned images (SIs) of the pelvis from a female cadaver are the best source of realistic three-dimensional (3D) models of the female urogenital system. The purpose of this research is to present SIs and outlined images of the female pelvis with improved quality, which may be used to produce 3D models to simulate virtual dissection or surgery of the female urogenital and adjacent structures. A pelvis of Korean female cadaver which preserved buttock curve was scanned with 3T MR and CT machines. The pelvis was embedded and milled at 0.1 mm intervals. All sectioned surfaces were photographed to create horizontal SIs. On the Photoshop, 73 structures were outlined in the SIs to create outlined images. Once the structures were outlined, volume and surface models of the structures could be produced. A total of 222 MRIs and 222 CTs of a female pelvis were obtained. 2,220 SIs of the pelvis were obtained (0.1x0.1x0.1mm3-sized voxels; 48 bits color). 222 outlined images of 73 structures were prepared at 1mm intervals. Once the structures were outlined, 3D volume and surface models of the structures were produced without the help of the computer programmers using MRIcro and Maya software. We have produced high quality SIs of the female pelvis accompanied by corresponding MRI and CT images. 3D volume and surface models of the female pelvic structures have been constructed. These computerized models may serve as the basis for future realistic medical simulation programs that may enhance clinical understanding of pelvic anatomy.


Subject(s)
Female , Humans , Anatomy, Cross-Sectional , Buttocks , Cadaver , Computer Simulation , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Pelvis , Tomography, X-Ray Computed , Urogenital System
2.
Journal of Korean Medical Science ; : 135-141, 2010.
Article in English | WPRIM | ID: wpr-64129

ABSTRACT

Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes.


Subject(s)
Aged , Humans , Male , Anatomy, Cross-Sectional , Brain/anatomy & histology , Brain Mapping , Cadaver , Image Processing, Computer-Assisted , Tomography, X-Ray Computed
3.
Korean Journal of Anatomy ; : 305-314, 2002.
Article in Korean | WPRIM | ID: wpr-650617

ABSTRACT

Serially sectioned images (MR, CT, and anatomical images) of the whole body are helpful in anatomy education because three dimensional images can be reconstructed with the serially sectioned images, and then the three dimensional images can be sectioned and rotated. To make the most important anatomical images of serially sectioned images, sectioned surfaces should be inputted into the personal computer after serial sectioning of the cadaver's whole body. In this study, equipments (digital camera and strobes) and techniques for inputting the sectioned surfaces into the personal computer to make anatomical images and for processing the anatomical images have been developed. By using these equipments and techniques, the anatomical images with the actual feature of the sectioned surfaces, the right alignment, and the constant brightness could be made. These anatomical images will be the basis for making good three dimensional images which are helpful in anatomy education.


Subject(s)
Education , Microcomputers
SELECTION OF CITATIONS
SEARCH DETAIL